Avenger Security Blog

Free Security System Evaluation
Upgrading a Legacy LenelS2 Access Control System with Brivo Managed Access Control Service.

Comprehensive Business Security Service Solutions
Buiness security should include burglar alarm, fire alarm, access control and video surveillance.

Home Security Monitoring Service Prices
Home security monitoring starting at $19.99 monthly.

Cost-effective Security Monitoring Service: Reprogramming Old Security Systems for Savings
Reprogramming old security systems Avenger Security's approach, it is just one facet of their comprehensive range of services.

Unlocking Security: Cloud Based Access Control by Alarmdotcom
Manage users, credentials and modify access control schedules in application.

Stay Ahead of Burglars with Our Smart Burglar Alarm Solutions in Austin, Texas
Keeping it simple affordable and professionals. Recommended minimum protection configuration done at cost.

Protect Your Business with Our Expert Security Solutions in Austin, Texas
Recommending burglar alarm, fire alarm, access control and video surveillance for your business in Austin, Texas.

Reliable Fire Alarm Monitoring Services in Austin, Texas: Keep Your Property Safe
Simple affordable fire alarm monitoring services in Austin, Texas starting at $50.00 monthly.

Powering Locks for Access Control
It is always best to run access control relay outputs dry. Power supplies should directly support the locks required power. It protects your hardware. Additionally, it is always best to configure doors fail secure. The locks should not require power to keep the door locked. Power should be provided to the lock to get the door to unlock. The output relay from the access control panel should complete the circut for power to the lock to unlock the door.

Cloud Access Control by Brivo
Brivo is the leader in managed access control. The Brivo access contol API can manage unlimited doors across multiple buildings. Contact Avenger Security to see how Brivo can help protect your building and people.

BRIVO ACS6100 SERIES CONTROL PANEL
Brivo ACS6100 Series Access Control Service. The ACS6000 main board can manage up to 30 doors. Multiple Brivo ACS6000 controls can be combined to handle facilities with more than 30 doors. Brivo is a top rated enterprise access control service sold by Avenger Security.

Installing Access Control - Fail Safe or Fail Secure
When getting access control on your facility you have options for locks, it is always best to avoid magnetics and other fail safe locks. These locks will unlock without power, so if battery back up or main power fails facility will be unlocked. Additionally, fail safe locks like magnetics block the AHJ - Fire department in event of emergency typically. Also, fail safe locks are required to be tied into the fire alarm system, fail safe locks have to be permitted by the AHJ and require two means of FAIL REX EXIT means >> fail safe locks make the configuration a more complex.

Request To Exit Sensor - Access Control
How the REX , Request To EXIT sensor should be used with access control systems. Best to avoid fail safe locks when getting access control, magnetic locks, create physical security concerns in power failures. Additionally, magnetics block the ability for Fire Department to access your facility in event of emergency.

Access Control - Perfect Electric Strike Installation
Highly recommend using template with high speed router when cutting an electric strike on a aluminum door for access control. The electric strike can be configured to your facility fail secure. The electric strike done properly will not block the AHJ. The key in KnoxBox will continue to open door in event of emergency for AHJ.

Advice When Installing Access Control
When configuring access control, use fail secure electric locks, don't change the existing egress on door, don't change how the door can be opened/unlocked from the outside with key, and don't change how the AHJ can gain entry thru the KNOX-BOX.

Access Control Upgrade
Cloud managed access control is able to be modified from a URL and or application. Operators can manage schedules, groups and/or users easily from anywere.

Smoke Alarms on 2 Wire Conventional Detector
The fire alarm circuit in a home must provide power thru all devices parallel, the smoke alarms in a home can not be wired in series using conventional 2 wire devices. 29.11.2.2 A single fault on the interconnecting means between multiple-station alarms shall not prevent single-station operation of any of the interconnected alarms.

Connecting 120 Volt AC Smoke Alarm Circuit to a security alarm system
Connecting 120 Volt AC power fire alarm to your security system is easy with an interconnection relay module. Most smoke alarm manufactures make a relay module that will throw a NO or NC circuit that can be programmed into a security alarm system to signal a fire alarm response from security system and local AHJ.

Home Smoke Alarm Requirements
Fire alarm protection requires smoke alarms in all bedrooms, outside each bedroom and on all levels of the home. Smoke Alarm Should Be Located on Each Level in Addition to Each Bedroom. In addition to smoke alarms outside of the sleeping areas and in each bedroom, Chapter 29 requires the installation of smoke alarm on each addtional level, including the basement. Smoke detectors have to have a parallel power source, and must be interconnected. In the event one device has an alarm, all interconneted devices must alarm.

Home Smoke Alarm Detectors & Security Systems
Home smoke alarms shall be replaced by code every 10 years. Avenger Security recommends replacing alll smoke alarms every 10 years to avoid nucannce alarms. NFPA 72 Code Chapter 29 Single and Multiple Station Alarms and Household Signaling Systems 29.11.1.4 (5) (a) Smoke alarms shall not remain in service longer than 10 years from the date of the manufacture unless otherwise provided by manufacturer's published instructions.

Old Fire Alarm System Inside Commercial Buildings
RULE §34.616 (5) Fire alarm system equipment replaced in the same location with the same or similar electrical and functional characteristics and listed to be compatible with the existing equipment, as determined by a fire alarm planning superintendent, may be considered a repair. The equipment replaced must comply with the currently adopted standards, but the entire system is not automatically required to be modified to meet the applicable adopted code. The local authority having jurisdiction (AHJ) must be consulted to determine whether to update the entire system to comply with the current code and if plans or a permit is required prior to making the repair.

Replace residential fire alarm devices after 10 years of use.
Home fire alarm smoke detectors should be replaced after 10 years of use. According to NFPA codes residential smoke fire alarm detectors should be replaced after 10 years of use.

NAPCO StarLink MAX2
Fire alarm system supervised dual path cellular communicators by Napco. StarLink Fire MAX2 Super dual service plan with AT&T and Verizon.

Fire Alarm Detectors by System Sensor
Low voltage fire alarm devices to detect smoke, heat & carbon monoxide. Fire alarm devices that can be used with professional security alarm systems.

Video Surveillance Quote
Managed professional video surveillance quote by Avenger Security. Video surveillance machine has a lifetime replacement warranty. Each video surveillance camera is configured to desired retention and resolution.

AIVO Networks Wi-Fi Network Bridge Configuration ANCP3005Q
Creating wireless network access points using the AIVO Networks Wi-Fi Network Bridge. Extend your camera network to remote locations via line of sight or WiFi. Use multiple CPE units to make a networks for video cameras.

Video Surveillance Service
video service is dependent on retention and resolution.

Video Surveillance in Austin
Managed video surveillance in Austin. Full service video service service by Avenger Security.

Remote Camera Guard Monitoring
Video guard monitoring - real people watching your cameras after hours and in times of need. Video guard monitoring is a less expensive option to onsite guards.

Video Surveillance Guard Monitoring Service
Video surveillance guard replacement monitoring services starts at $70.00 monthly.

Eagle Eye Networks Cloud Video Surveillance Options: Analytics and Artificial Intelligence
Cloud managed video surveillace with analitics allows using and giving access to others super easy.

Access Control System & Video System Integrations: Fortifying Security Infrastructure
Acess control and video surveillance sytems should be integrated.

ADT Safewatch Pro 3000 home security reprogram Alula Bat 4G 5G
ADT Safewatch Pro 3000 home security system reprogram with the Alula Bat 4G 5G cellular interactive.

New or Used Home Security System

Use Any Security System
We can typcially use the security alarm system you already have.

Home Security System w Monitoring Service Starting at $19.99 Monthly
Home security monitoring service starting at $19.99 monthly.

Security Systems: The Best Alarms for Austin Homeowners
Control your alarm system from anywhere. Get notifications, video surveillance and more.

Stay Safe, Austin: Choosing the Right Home Security System
Arm and Disarm your home security system from application.

Austin's Best: Top Home Security System s for 2024
Options for home security monitoring service in Austin, Texas

Your Home Security: Top-Rated Alarms in Austin
Keeping home security simple and affordable. Long term home security protection you can count on.

Travis County Sheriff Requires Alarm Permit
Travis County requires Alarm Permit


TEXAS ADMINISTRATIVE & OCCUPATIONS CODES
TEXAS DEPARTMENT OF INSURANCE ADMINISTRATIVE CODE Sec. 6002.003. EFFECT ON LOCAL REGULATION. (a) This chapter and the rules adopted under this chapter have uniform force and effect throughout this state. A municipality or county may not enact an ordinance or rule inconsistent with this chapter or rules adopted under this chapter. An inconsistent ordinance or rule is void and has no effect. (2) pay any fee or franchise tax to the political subdivision; or (d) Notwithstanding any other provision of this section or Section 6002.155, a municipality or county may require a registered firm to obtain a permit and pay a permit fee for the installation of a fire alarm or fire detection device or system and require that the installation of such a system be in conformance with the building code or other construction requirements of the municipality or county and state law. (e) Notwithstanding Subsection (d), a municipality or county may not impose qualification or financial responsibility requirements other than proof of a registration certificate. (f) A political subdivision may not require a registered firm, a license holder, or an employee of a registered firm to maintain a business location or residency within that political subdivision to engage in a business or perform any activity authorized under this chapter. TEXAS DEPARTMENT OF PUBLIC SAFETY OCCUPATIONS CODE - Sec. 1702.134. COMPANY LICENSE HOLDER EXEMPTIONS FROM CERTAIN LOCAL REGULATIONS. (a) A company license holder or an employee of a company license holder is not required to obtain an authorization, permit, franchise, or license from, pay another fee or franchise tax to, or post a bond in a municipality, county, or other political subdivision of this state to engage in business or perform a service authorized under this chapter. (b) A municipality, county, or other political subdivision of this state may not require a payment for the use of municipal, county, or other public facilities in connection with a business or service provided by a company license holder, except that a municipality may impose and collect:

Alarm.com V729 4MP Outdoor Floodlight Camera
ADC-V729AC 4MP Outdoor Floodlight Camera

Aiphone Video Intercom Access Control
Aiphone video intercom with integrated access control. Video verified access control.

Reliable Security Protection

Emergency Monitoring Response
Emergnency monitoring response can be used to detect burglary, fire, thefts, water, gas, motion, tamper etc. Avennger Security provides emergency monitoring response to Austin and surrounding areas.

Austin Police Department Requires Alarm Permit
City of Austin police department required alarm permit application. The city of Austin requires permit to have or operate a alarm system. City of Austin alarm permit is required if you have are using an alarm system in your home or building.

Alarm System Event Notification
Interactive Alarm System Event Notifications are sent to let you know what is going on when you are away. Alarm System recording system activity in cloud application interface.

Remote Security Alarm Arm/Disarm
Full Service cellular interactive security system alarm monitoring emergency response starting at $29.99 Monthly. No long term service agreement is required to establish services.